Accelabar
Steam Metering with Accelabar:
Application: Steam flow at a large
university over wide turndowns. Steam flow rates vary
based on changing demand (winter vs. summer, breaks,
etc.).
Pressure/Temperature: 125# Steam
Flow Rate: 2,000 PPH to 30,000 PPH
Pipe Sizes: 8” Pipes
Accelabar® Advantages:
Ability to Accurately Measure Wide Range of
Steam Flows.
The Accelabar nozzle accelerates the steam velocity. The
Verabar located within the nozzle accurately measures
and significantly increases the differential pressure
output to increase the operating range (turndown).
No Straight Run Requirements.
Stabilization and linearization of the steam velocity
profile within the throat of the nozzle eliminates the
need for any upstream run.
No Piping Modifications Required.
Other technologies require a reduction in pipe size (to
increase the velocity to measurable ranges), including
additional straight lengths of pipe. The Accelabar did
not require a reduction in pipe size and was installed
within only a 22” face-to-face dimension.
Results:
Customer comment: “This time of year (summer) the steam
flow on this steam line is low. We have been checking
the readings and are pleased with the results. I feel
this added accuracy on the lower end will be a real plus
for our billing department. Thanks for your help.”
|