Chandak Instruments Pvt. Ltd.

The Flow Measurement Solution Provider

IMR 2800IR

IR - FLUE GAS ANALYZER

imr2800p

THE ALL NEW IMR 2800 IR Series

New Features:

  • Latest sensor technology for a more accurate measurement and longer life time
  • Improved interior design for easier service and better unit protection
  • Continuously and simultaneously measuring up to 18 parameters
  • Larger display for a better reading
  • Applications: Boilers, Burners, Engines, Turbines, Cars, Trucks, Plants, Chemical Industries, Steel Plants, Refineries, etc

Standard Features:

  • Portable combustion gas analyzer housed in a rugged aluminum case
  • Simultaneous measurement of
    • O2 Oxygen
    • NO2 Nitrogen dioxide
    • CO Carbon Monoxide
    • SO2 Sulfur dioxide
    • NO Nitric oxide
    • TG Flue-gas temperature
    • TA Ambient Air temperature
  • Calculation of following parameters
    • Losses / Efficiency
    • NOx Nitrogen Oxides
    • Excess Air / Lambda
    • CO2 Carbon Dioxide
  • Automatic zero calibration
  • Integrated self-check program
  • Simultaneous display parameters on the illuminated display
  • Printer with programmable print out cycles
  • Standard deviation and average value calculation
  • Draft measurement with optional upgrade for differential draft and velocity measured with a Pitot tube
  • Unit selection : ppm – mg/Nm3 – mg/Nm3(ref O2)
  • Gas sampling probe E – length 0.8 ft (250mm), hose 8 ft (2.5m)
  • Rechargeable battery with charger
  • Power supply 110V or 230V

Optional Features:

imr2800p

  • HCl, N2O, CL2, H2, NH3, HC or H2S measurement
  • CO2, CH4/HC and N2O NDIR sensors available
  • Speed RPM
  • Prepared for high temperature measurement (up to 2732 °F / 1500 °C)
  • Gas sampling probes with different lengths
  • Soot measurement
  • Pitot Tube
  • Gas Flow m/s
  • Additional Instruments: RPM Meter, Soot Meter

PARAMETER PRINCIPLE RESOLUTION ACCURACY RANGE** STANDARD
O2 Oxygen Electro-chemical cell 0.1 Vol.% ± 0.2 Vol. % 0 - 20.9 Vol. %
CO Carbon monoxide NDIR 0.001 Vol.% Z 0 - 10/20 Vol.%
CO2 Carbon dioxide NDIR 0.01 Vol.% ± 0.2 Vol. % 0 - 20 Vol.%
HC/CH4 Hydrocarbons NDIR 0.1 % Z 0 - 100% LEL  
NO Nitric oxide Electro-chemical cell 1 ppm Z 0 - 2000 ppm
NO2 Nitrogen dioxide Electro-chemical cell 1 ppm Z 0 - 100 ppm
SO2 Sulfur dioxide Electro-chemical cell 1 ppm Z 0 - 4000 ppm
H2S Hydrogen Sulfide Electro-chemical cell 1 ppm Z 0 - 200 ppm  
TG Flue gas temperature NiCr - Ni thermocouple 1 K ± 2 % -4°F - 2192°F

0°C - 1200°C
TA Air temperature Semiconductor 1 K ± 0.2 K -4°F / 248°F

0°C - 120°C
P Draft Solid state 0.01 hPa ± 2 % ± 40 hPa  
NOx Nitrogen oxides Calculation 1 ppm Z 0 - NOx max  
NH3 Ammonia Electro-chemical 1 ppm Z 0 - 1000/5000 ppm  
N2O Nitrous Oxide NDIR 0.001 Vol. % Z 0 - 1 Vol. %  
HCl Hydrogen Chloride Electro-chemical 1 ppm Z 0 - 200 ppm  
Cl2 Chlorine Electro-chemical 1 ppm Z 0 - 5000 ppm  
H2 Hydrogen Electro-chemical 1 ppm Z 0 - 10000 ppm  
Losses / Efficiency Calculation 0.1 % ± 0.1 % 0 - 99.9 %
Excess Air / Lambda Calculation 0.1 % ± 0.1 % 1.0 - 9.99
Soot Filter paper method     0 - 9  
Velocity with Pitot tube Solid state 0.01 m/s ± 2 % 0 - 80 m/s  
RPM Meter Solid state 100 RPM ± 2 % 180 - 10000 RPM  
** Different/customized ranges available. Equipped with a maximum of 8 gas sensors

Z = 0 - 20 % of whole measurement range ± 5 %

21 - 100 % of whole measurement range ± 1 % of displayed measurement

MODEL - IMR 2800 IR
Dimensions (inch): 15 x 6.5 x 12.4 = (375mm x 165mm x 300mm)
Weight: 17 lbs. (8 kg)

PART-NO. - IMR 28100

Testimonials

“Understanding the problem to extend practical solution is something what we have experienced. Their analysis & solution helped Dalmia Cement save recurring energy cost & efficiency in the process to improve quality of our material”

– Dalmia Cements Limited

“Installation & Supervision has been key to flow measurement industry. Chandak Instruments Pvt. Ltd.’s focus on appropriate installation helped to achieve the expected results out of the flow meter”

Arabi Enertech, Kuwait