Leak Detection
HOFFER INSERTION METERS USED FOR
LEAK DECTION IN PIPELINE
Hoffer Flow Controls
continues to supply many insertion type turbine flowmeters
to the petroleum pipeline industry. This type of meter commonly used for leak detection
and not custody transfer. Custody transfer applications
are addressed with in-line axial flowmeters such as the
Hoffer API Series. Leak detection flow applications, for
checking the integrity of the pipeline, can be addressed
with the HP Series of insertion turbine flowmeters.
The principle of operation for an insertion type turbine
flowmeter is much the same as an in-line turbine flowmeter.
The insertion meter includes a rotor assembly and pickup
coil. The flowmeter measures velocity at a specific point
in the fluid stream. Volumetric flow can be inferred provided
the I.D. of the line is known. Accuracies can approach ±0.25%
depending on the type of transmitter specified with the
flowmeter.
Insertion turbine meters
provide multiple advantages when compared both to in-line
turbine flowmeters and other types of flowmeter technologies.
These advantages include low cost, negligible pressure drop,
low installation costs, minimal potential points of leakage,
and avoidance of high pumping costs. Additionally, the HP
insertion turbine flowmeter can be specified for use in
velocities up to 50 FPS. This allows pipeline companies
to move a maximum amount of product in the shortest time
possible.
Leak detection and pipeline integrity is not only essential
to the bottom line for the pipeline company, it is an environmental
issue. In California, in particular, Hoffer has supplied
insertion turbine flowmeters for pipeline integrity verification.
Many of the petroleum products being measured include the
additive MTBE. Proper selection of the flowmeter seal is
essential for any application, however, is sometimes more
challenging with various additives factored into the equation.
Hoffer has successfully specified and supplied the insertion
turbine flowmeter for a wide cross section of pipeline applications.
The HP Series flowmeters
are available in both low pressure
and high pressure versions. The unit produces a frequency
pulse output. Hoffer can supply either a pulse producing
preamplifier or an analog signal converter with the HP meter.
The recent introduction of the HIT-1 smart signal converter
allows user to take advantage of the excellent repeatability
of the HP flowmeter. This means that users can achieve ±0.25%
linearity over a 10:1 flow turndown range when they specify
the HIT-1transmitter with the HP insertion turbine flowmeter.
Whether your flow application calls for a linearity of
±0.15%, ±0.25%, ±0.5% or ±1% turbine flowmeter, call us.
We design and manufacture a wide variety of turbine flowmeter
solutions for gas and liquid applications. Let us put our
flow expertise to work for you.
Rep Spotlight
TALON Technical sales provides representation for the
Hoffer product line in South Texas. They have handled our
line in this region for just over a year’s time. Within
this short period of time, they have proven to be one of
our most active rep groups in the US. As a regroup, they
don’t come any better than the folks at TALON. Their group
includes technically capable individuals who support their
selling efforts both inside and outside of their office.
Customers in South Texas, feel free to contact TALON to
discuss any of your flow measurement needs. Their local
phone number is 281-999-8588.
Redi-pulse Coil Now Intrinsically
Safe
For intrinsically safe requirements, Hoffer has introduced
an intrinsically safe Redi- Pulse coil. This coil meets
intrinsic safety to CSA (with NRTL/C) and CENELEC. The I.S. Redi-pulse
features a self-contained preamplifier in magnetic and modulated
carrier types. The I.S. Redi-pulse coils are beneficial
by allowing the user to produce a conditioned pulse output
without a separate signal conditioner. The I.S. Redi-Pulse
allows users to eliminate bulky junction boxes and running
long lengths of conduit. Additionally, these pickup coils
offer noise immunity and greater transmission capability.
Pulse output signal options include TTL/CMOS and open collector.
A user supplied power of 7.5-28 VDC is required to support
the low power DC version and 13-28 VDC to support the high
power DC version. Now available. Cal today.in¼"through3"sizes.
Low Cost Flow Solution
Looking for a low cost industrial flow solution? Try
, featuring a stainless steel paddle wheel rotor design.
The offers a rugged, dependable solution to users at the
price of plastic paddle wheel meters. read for Liquid Utility
and OEM applications. Call or more information on this new
series.
Provides digital pulse output.
Product Catalog on CD
It’s convenient, it’s easy to use, it’s a great reference
tool - the Hoffer Flow Controls CD-ROM Product Catalog.
The CD includes Hoffer Technical Data Sheets, our popular
Engineering Guide, the Collection Brochure, and more. If
you need information on turbine flowmeters and electronics,
request this CD for comprehensive data. Provide your gas
flow information and the Hoffer gas sizing program will
size your gas meter. This CD also includes installation
drawings for your reference. Request your Hoffer Product
Catalog on CD by either calling us at 800-628-4584 or visiting
our website www.hofferflow.com.
|